BHNCT (NOISE CUT TRANSFORMER) |
|
Cause of Noise |
|
|
|
High-frequency rates from time to time reaching dozens MHz
Mainly transterre by way of Power Line of electric, controlling and power-supplying hdvices.
Inceasing number of devices demanding power
▷ Signalization occurring very commonly from varied devices
Beccones very weak to surge and noises
▷ Increasing number of devices noise-affected |
|
|
|
Preventive Measures |
|
|
|
Noise Filter
Surge Protector
NCT (Noise Cut Transformer) |
|
|
|
Head-to head Comparisons among Preventive Measures |
|
Category |
|
Property |
|
Note |
|
Noise Filter
Surge Protector |
|
Most common means.
Functionally limited as the power line and circuit are not nsulatable. |
|
Used mostly by
domestic Companies |
|
NCT |
|
Cuts noises in principle by breaking Ground Loop of noises and surges for insulation.
Manifests higher noise-controlling properties |
|
Used mostly by foreign
Companies |
|
|
|
Principle |
Conventional : Entire magnetic fluxes from "Pri." transmitted to "Sec." for the perfect induction.
NCT : Low-frequency magnetic fluxes selectively transmitted to "Sec.", with harmonic fluxes eliminated in the middle(within magnetic circuit) before reaching "Sec."
(by way of Metal Pin / Shielding Method)
Perfect control of electric capacity and induction feasible for the eventual noise cut. |
|
Operational property |
|
Features perfect insulation between PS and SS (very much improved from the conventional shielded transformer)
Adopts Multi-shield System to maximize shielding property.
Sets input and output apart from each other by way of the foregoing perfect insulation
Input / Output wiring adopts 'Shielded Twist Wiring' to maximize shielding property against the spatial noise. |
|
|
Operational example |
|
|
Link NCT at where the device received input to get rid of noises and surges to
supply 'Clean Power'
▷ Mechanically protects device, extends life, prevents mal-operation
and damage. |
|
|
Strengths |
|
No further earthing necessary while bringing the mechanical property of the device all along.
▷ Noise cut also feasible at where earthing is not spatially feasible
Impedance matching no longer becomes al matter.
Insulation provided for anti-surge property.
Less power leaked over device operation.
▷ Best-fit for medical devices and any other devices subject to the power leakage limit.
Effective means of cutting bi-directional noises
▷ Bi-directionally cuts noises led-in or generated within the device(Switching noises)
Effective means of cutting noises with wider frequency (up to dozens KHz) thanks to the advanced structural property compared to the conventi conventional means of Noise Filter, etc.. |
|
|
Use |
|
Controller Systems(PLC / ROBOT / DCS / CONTROLLER)
Precise measuring devices
Broadcasting / Audio-visual devices
Medical devices
Any other devices subject to noise influence |
Office automation devices (OA / FA)
Semi-conductor manufacture facilities
Devices subject to surge influence
Rail network, subway signaling and communication devices
|
|
|
NCT와 TRANSFORMER 특성비교 |
|
일반 TRANSFORMER |
실드 TRANSFORMER
(ISOLATION) |
NOISE CUT TRANSFORMER |
|
|
|
|
|
Normal Mode. Common Mode
Noise 모두통과함. |
Normal Mode Noise는 통과 Common
Mode의 Noise의
저주파대는 감쇠되나
높은 대역은 모두 통과함. |
Normal Mode. Common Mode의
Noise 모두 감쇠함. |
|
|
|
주의사항 |
기기와 인명을 보호하기 위하여 NCT의 본체 및 외함은 반드시 접지하여야 합니다.(전기기술 기준의 의거함) |
|
|
|
|
|
접지결선 방식 |
|
(1) 전원측 접지 상황이 양호한 경우 |
(2) 전원측 접지가 없거나 접지 상황이 불량한 경우 |
(3) SG가 있는 경우(단, 전원측 접지 조건 양호) |
|
|
|
|
|
S1 : 전원측 접지에 연결
S2, SE : COMMON하여 부하기기 FG에 연결 |
S1 : 접지하지 않음
S2, SE : COMMON하여 부하기기 FG에 연결 |
S1 : 전원측 접지에 연결
S2 : 부하기기 SG에 연결
SE : 부하기기 FG에 연결 |
|
|
|
SG : Slgnal Ground
FG : Frame Ground |
|
|
|
BHNCT-HC Series |
|
Graphs of Noise - suppression Characteristics |
|
|
1KVA (COMMON MODE) |
|
1KVA (NORMAL MODE) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
3KVA (COMMON MODE) |
|
3KVA (NORMAL MODE) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
5KVA (COMMON MODE) |
|
5KVA (NORMAL MODE) |
|
|
|
|
|
|
|
|
|
|
|
|
|